Twin traffic light display indicate machine status
Suitable for hot (max 50°C) or cold water supply at 2 to 4 bar dynamic supply pressure
Machines fitted to cold water supplies will not be capable of running repeated short cycles.
The cycle time will automatically be extended to allow recovery of correct operating temperatures
Wash temperature 60°C (adjustable)
Rinse temperature 65°C (adjustable)
C Range - Undercounter
C402
Width x Depth x Height mm
440 x 540 x 665mm
Feet Height
5mm-15mm
Basket size
390x390mm
Maximum useable height
300mm
Door Opening
320mm
Cycle times
90/120/150 Seconds
Water consumption per cycle
1.9 Litres
Wash tank capacity
10 Litres
Phase - Options
Single Phase Only
Power – Single Phase Options
2.8kW(13Amp)
Power – Three Phase
N/A
Detergent pump
Peristaltic-non timed
Rinse aid pump
Peristaltic-non timed
Drain pump
Optional
Breaktank
No
Water supply pressure
2 to 4 Bar
Body Construction
Partial Double Skin
Door/Hood Construction
Double Skin
Scrap Trays
Yes
Internal Rinse Booster Pump
N/A
Number Of Cycles
3
Total Maximum Load(as supplied)
2.8kW(13Amp) Single Phase
[{"file":"/core/media/media.nl?id=5538890&c=1120086&h=5a906b8a9b8cf15c9982","title":"C402 door open (7mb)","image":"/core/media/media.nl?id=5538891&c=1120086&h=8f2f851542c716747955"},{"file":"/core/media/media.nl?id=5538889&c=1120086&h=44df23d5bb23458ba31b&_xt=.pdf","title":"C402 wiring diagram (5.5mb)","image":"/core/media/media.nl?id=5538894&c=1120086&h=ce6c2cc54a80c05fa2a6"},{"file":"/core/media/media.nl?id=5538888&c=1120086&h=e4309b383beee308b792&_xt=.pdf","title":"C402 user and install instructions (3.5mb)","image":"/core/media/media.nl?id=5538893&c=1120086&h=638a5c7b915fa26fd411"},{"file":"/core/media/media.nl?id=5538887&c=1120086&h=1c0a19e5ec50787d2669&_xt=.pdf","title":"C402 parts diagram (4.8mb)","image":"/core/media/media.nl?id=5538892&c=1120086&h=79823e3b8b8332656515"}]